1. modular design, N+X redundancy, hot plugging
2. Strong load adaptability and loading capacity, and excellent power grid applicability
3. overall efficiency>95%, input power factor> 0.99, (THDi)<3%
4. Dual DSP for independent control of power module, no single point of failure
5. Digital control of rectification, inverter, charging and discharging via DSP
6. Integrated and packaged IGBT
7. LCD+LED Touch screen display, easier to maintenance
8. battery management system
9. Parallel connection via the parallel card
10. Easy to install, space-saving.
11. Redundancy and intelligent adjustable-speed fan, low noise, low power consumption
12. Integrated distribution systemwith low investment by user
13. Good matching performance with motor
14. DC Starting(cold boot) for easy operation
15. Three-proofing treatment of all circuit boards.
16. Optional Standard battery bank or extension battery bank
BKH Series Specification
M1-10KVA per module
Awoṣe (full configured ) BKH-M1A | BKH-M1A-G30K | BKH-M1A-G60K | BKH-M1A-G100K | BKH-M1A-G120K |
Capacity | 10KVA-30KVA | 10KVA-60KVA | 10KVA-100KVA | 10KVA-120KVA |
Power module capacity | 10KVA | |||
Power module weight | 14KG | |||
Power module number(MAX) | 3 | 6 | 10 | 12 |
Physical parameter | ||||
Power module size (W*D*H) | 19"*509mm*"2U | |||
Power module weight | 14KG/unit | |||
Cabinet size (W*D*H)mm | 600*800*1600 | 600*800*2000 | ||
Cabinet weight | 180 | 197 | 245 | 260 |
Mains input(AC ) | ||||
Phase | 3 alakoso 4 wires/single phase 2 wires+G | |||
Voltage range | 291~492V (line-line) full load; | |||
Frequency range | 30Hz~80Hz | |||
THDi | <3% | |||
Power factor | 0.995 | |||
Bypass range | -10%~10% (can customized -10%~-30%, +10%~+20%) | |||
Batiri | ||||
Connection type | positive and negative battery supply | |||
Rated voltage | +/- 384VDC (+/-32*12V series) | |||
Battery number | 64pcs/set | |||
Charging current | 20% * system power(battery capacity) | |||
Output(inverter) | ||||
Output voltage | 3 phase 380VAC/1 phase 220VAC +G | |||
Voltage regulation | <+/-1% | |||
Phase lock range | 50Hz/60Hz +/-5Hz;(self frequency 50Hz/60Hz+/-0.01Hz) | |||
Output frequency | 50Hz/60Hz+/-0.01Hz (if phase locked then mains frequency) | |||
Power factor | 0.9 | |||
Crest factor | 3:1 | |||
THDu | THD<1.0% (linear load), THD<3%(non-linear load) | |||
Three phase voltage unbalance degree | alance load: 0.2% 100% unbalance load : 0.5% | |||
Dynamic voltage transient range | <2% | |||
Transient Recorery Time | 0ms | |||
Three phase voltage deviation | mains:0.1; battery :0.1 | |||
Overload capacity | 125% for 10min: 150% for 1min; >150% for 200ms (linear load) | |||
System efficiency | >94% | |||
Environment indicator | ||||
Noise | <60dB @100%load, cooling fan adopt intelligent speed control | |||
Display | touch screen LCD+LED | |||
Interface | standard: RS232, RS485, dry contacts, SNMP card optional | |||
Operation temperature | temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C Altitude(m): <1000, 1000m-2000m above every 100m reduce 1% | |||
IP class | IP30( Removable dust filter) | |||
NOTES: subject to change without further notice! |
M2-20KVA per module
Awoṣe | BKH-M2A-T60K | BKH-M2A-T100K | BKH-M2A-T160K | BKH-M2A-T200K |
Capacity | 20KVA-60KVA | 20KVA-100KVA | 20KVA-160KVA | 20KVA-200KVA |
Power module capacity | 20KVA | |||
Module size(W*D*H) | 19"*690mm*"3U | |||
module weight | 28KG/unit | |||
Mains input(AC ) | ||||
Phase | 3 phase +N+PE | |||
Voltage range | 291~492 V(line-line) full load; 200V~291V linearly decrease | |||
Frequency range | 35Hz~70Hz | |||
THDi | <3%(full linear load) | |||
Power factor | 0.995 | |||
Bypass range | -10%~10% (can customized -10%~-30%, +10%~+20%) | |||
Batiri | ||||
Connection type | positive series and negative series battery | |||
Rated voltage | +/- 240VDC (positive and negative each 20pcs*12V series), can customized | |||
Battery number | 40pcs/set (can customize 30~50pcs/set optional) | |||
Charging current | 20% * system power(battery capacity) | |||
Output(inverter) | ||||
Output voltage | 380VAC 3 alakoso 4 wires+PE | |||
Voltage regulation | <+/-1% | |||
Phase lock range | 50Hz/60Hz +/-5Hz;(self frequency 50Hz/60Hz+/-0.01Hz) | |||
Output frequency | 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked) | |||
Power factor | 1 | |||
Crest factor | 3:1 | |||
THDu | THD<2.0% (linear load), THD<3%(non-linear load) | |||
Three phase voltage unbalance degree | balance load: 0.5% 100% unbalance load : 1% | |||
Dynamic voltage transient range | <3% | |||
Transient Recorery Time | 0ms | |||
Three phase voltage deviation | mains:0.4; battery :0.3 | |||
Transfer time | mains to battery: 0ms; inverter to bypass: 0ms | |||
Overload capacity | 125% for 10min: 150% for 1min; >150% for 200ms (linear load) | |||
System efficiency | >96% | |||
Environment indicator | ||||
Noise | <60dB @100%load, cooling fan adopt intelligent speed control | |||
Display | touch screen LCD+LED | |||
Interface | standard: RS232, RS485, dry contacts, SNMP card optional | |||
Operation temperature | temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C Altitude(m): <1000, 1000m-2000m above every 100m reduce 1% | |||
IP class | IP30( Removable dust filter) | |||
Physical parameter | ||||
Cabinet size (W*D*H)mm | 600*800*1250 | 600*1100*2000 | 600*1100*2000 | |
Cabinet weight | 130 | 295 | 305 | 310 |
Modules No.(Max) | 3 | 5 | 8 | 10 |
NOTES: subject to change without further notice! |
M3-30KVA per module
Awoṣe | BKH-M3A-T90K | BKH-M3A-T150K | BKH-32A-T240K | BKH-M3A-T300K |
Capacity | 30KVA-90KVA | 30KVA-150KVA | 30KVA-240KVA | 30KVA-300KVA |
Power module capacity | 30KVA | |||
Module size(W*D*H) | 19"*690mm*"3U | |||
module weight | 36KG/unit | |||
Mains input(AC ) | ||||
Phase | 3 phase +N+PE | |||
Voltage range | 291~492 V(line-line) full load; 200V~291V linearly decrease | |||
Frequency range | 35Hz~70Hz | |||
THDi | <3%(full linear load) | |||
Power factor | 0.995 | |||
Bypass range | -10%~10% (can customized -10%~-30%, +10%~+20%) | |||
Batiri | ||||
Connection type | positive series and negative series battery | |||
Rated voltage | +/- 240VDC (positive and negative each 20pcs*12V series), can customized | |||
Battery number | 40pcs/set (can customize 30~50pcs/set optional) | |||
Charging current | 20% * system power(battery capacity) | |||
Output(inverter) | ||||
Output voltage | 380VAC 3 alakoso 4 wires+PE | |||
Voltage regulation | <+/-1% | |||
Phase lock range | 50Hz/60Hz +/-5Hz;(self frequency 50Hz/60Hz+/-0.01Hz) | |||
Output frequency | 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked) | |||
Power factor | 1 | |||
Crest factor | 3:1 | |||
THDu | THD<2.0% (linear load), THD<3%(non-linear load) | |||
Three phase voltage unbalance degree | balance load: 0.5% 100% unbalance load : 1% | |||
Dynamic voltage transient range | <3% | |||
Transient Recorery Time | 0ms | |||
Three phase voltage deviation | mains:0.4; battery :0.3 | |||
Transfer time | mains to battery: 0ms; inverter to bypass: 0ms | |||
Overload capacity | 125% for 10min: 150% for 1min; >150% for 200ms (linear load) | |||
System efficiency | >96% | |||
Environment indicator | ||||
Noise | <65dB @100%load, cooling fan adopt intelligent speed control | |||
Display | touch screen LCD+LED | |||
Interface | standard: RS232, RS485, dry contacts, SNMP card optional | |||
Operation temperature | temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C Altitude(m): <1000, 1000m-2000m above every 100m reduce 1% | |||
IP class | IP30( Removable dust filter) | |||
Physical parameter | ||||
Cabinet size (W*D*H)mm | 600*800*1250 | 600*1100*2000 | 600*1100*2000 | |
Cabinet weight | 130 | 295 | 305 | 310 |
Modules No.(Max) | 3 | 5 | 8 | 10 |
NOTES: subject to change without further notice! |
M4-40KVA per module
Awoṣe | BKH-M4A-T120K | BKH-M4A-T200K | BKH-M7A-T320K | BKH-M4A-T520K |
Capacity | 40KVA-120KVA | 40KVA-200KVA | 40KVA-320KVA | 40KVA-520KVA |
Power module capacity | 40KVA | |||
Module size(W*D*H) | 19"*690mm*"3U | |||
module weight | 39KG/unit | |||
Mains input(AC ) | ||||
Phase | 3 phase +N+PE | |||
Voltage range | 291~492 V(line-line) full load; 200V~291V linearly decrease | |||
Frequency range | 35Hz~70Hz | |||
THDi | <3%(full linear load) | |||
Power factor | 0.995 | |||
Bypass range | -10%~10% (can customized -10%~-30%, +10%~+20%) | |||
Batiri | ||||
Connection type | positive series and negative series battery | |||
Rated voltage | +/- 240VDC (positive and negative each 20pcs*12V series), can customized | |||
Battery number | 40pcs/set (can customize 30~50pcs/set optional) | |||
Charging current | 20% * system power(battery capacity) | |||
Output(inverter) | ||||
Output voltage | 380VAC 3 alakoso 4 wires+PE | |||
Voltage regulation | <+/-1% | |||
Phase lock range | 50Hz/60Hz +/-5Hz;(self frequency 50Hz/60Hz+/-0.01Hz) | |||
Output frequency | 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked) | |||
Power factor | 1 | |||
Crest factor | 3:1 | |||
THDu | THD<2.0% (linear load), THD<3%(non-linear load) | |||
Three phase voltage unbalance degree | balance load: 0.5% 100% unbalance load : 1% | |||
Dynamic voltage transient range | <3% | |||
Transient Recorery Time | 0ms | |||
Three phase voltage deviation | mains:0.4; battery :0.3 | |||
Transfer time | mains to battery: 0ms; inverter to bypass: 0ms | |||
Overload capacity | 125% for 10min: 150% for 1min; >150% for 200ms (linear load) | |||
System efficiency | >96% | |||
Environment indicator | ||||
Noise | <68dB @100%load, cooling fan adopt intelligent speed control | |||
Display | touch screen LCD+LED | |||
Interface | standard: RS232, RS485, dry contacts, SNMP card optional | |||
Operation temperature | temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C Altitude(m): <1000, 1000m-2000m above every 100m reduce 1% | |||
IP class | IP30( Removable dust filter) | |||
Physical parameter | ||||
Cabinet size (W*D*H)mm | 600*800*1250 | 600*1100*2000 | 600*1100*2000 | 1200*1100*2000 |
Cabinet weight | 130 | 295 | 305 | 578 |
Modules No.(Max) | 3 | 5 | 8 | 13 |
NOTES: subject to change without further notice! |
M5-50KVA per module
Awoṣe | BKH-M5A-T200K | BKH-M5A-T300K | BKH-M5A-T500K | BKH-M5A-T600K |
Capacity | 50KVA-200KVA | 50KVA-300KVA | 50KVA-500KVA | 50KVA-600KVA |
Power module capacity | 50KVA | |||
Module size(W*D*H) | 19"*690mm*"3U | |||
module weight | 39KG/unit | |||
Mains input(AC ) | ||||
Phase | 3 phase +N+PE | |||
Voltage range | 291~492 V(line-line) full load; 200V~291V linearly decrease | |||
Frequency range | 35Hz~70Hz | |||
THDi | <3%(full linear load) | |||
Power factor | 0.995 | |||
Bypass range | -10%~10% (can customized -10%~-30%, +10%~+20%) | |||
Batiri | ||||
Connection type | positive series and negative series battery | |||
Rated voltage | +/- 240VDC (positive and negative each 20pcs*12V series), can customized | |||
Battery number | 40pcs/set (can customize 30~50pcs/set optional) | |||
Charging current | 20% * system power(battery capacity) | |||
Output(inverter) | ||||
Output voltage | 380VAC 3 alakoso 4 wires+PE | |||
Voltage regulation | <+/-1% | |||
Phase lock range | 50Hz/60Hz +/-5Hz;(self frequency 50Hz/60Hz+/-0.01Hz) | |||
Output frequency | 50Hz/60Hz+/-0.01(turn into mains frequency if phase locked) | |||
Power factor | 0.9 | |||
Crest factor | 3:1 | |||
THDu | THD<2.0% (linear load), THD<3%(non-linear load) | |||
Three phase voltage unbalance degree | balance load: 0.5% 100% unbalance load : 1.5% | |||
Dynamic voltage transient range | <3% | |||
Transient Recorery Time | 0ms | |||
Three phase voltage deviation | mains:0.4; battery :0.3 | |||
Transfer time | mains to battery: 0ms; inverter to bypass: 0ms | |||
Overload capacity | 125% for 10min: 150% for 1min; >150% for 200ms (linear load) | |||
System efficiency | >95% | |||
Environment indicator | ||||
Noise | <70dB @100%load, cooling fan adopt intelligent speed control | |||
Display | touch screen LCD+LED | |||
Interface | standard: RS232, RS485, dry contacts, SNMP card optional | |||
Operation temperature | temperature: -10C ~+40C; humidity 0%~98%; storage temperature -25C~+75C Altitude(m): <1000, 1000m-2000m above every 100m reduce 1% | |||
IP class | IP30( Removable dust filter) | |||
Physical parameter | ||||
Cabinet size (W*D*H)mm | 600*800*1250 | 600*1100*2000 | 1200*1100*2000 | |
Cabinet weight | 295 | 305 | 578 | 600 |
Modules No.(Max) | 4 | 6 | 10 | 12 |
NOTES: subject to change without further notice! |
The main parts of the BKH Modular ups.
Some modules we produced in the factory.
Ibeere:: Idi ti yan wa?
A: A jẹ China Ṣiwaju awọn oke&oorun eto Olupese, 11 iriri ọdun ni ṣiṣe ati titaja
awọn oke & awọn ọja oorun.
100% Ayewo QC Ṣaaju Sowo.
Didara to dara julọ & Iṣẹ ti o dara julọ pẹlu idiyele Idije.
Iṣẹ lẹhin-tita to dara: 2 atilẹyin ọja ọdun ati ti o ba ṣeeṣe a pese fifi sori ati tunṣe lori aaye
Gbogbo awọn ọja wa ni ijẹrisi CE, ISO9001, ISO14001, OHSAS18000, Ijẹrisi TLC, ati Kannada
iwe eri itoju agbara
Ọja ni wiwa awọn 100 awọn ilu ati awọn orilẹ-ede ni gbogbo agbaye. Ni ọfiisi ni Pakistan, Ọstrelia, abbl.
Ti o ba ni diẹ ninu awọn iṣoro nipa FEPS jara Ipese agbara pajawiri , tabi fẹ lati mọ awọn alaye diẹ sii nipa 3 awọn ipele alakoso,3 eto awọn ipele,480 folti 3 awọn ipele alakoso,3 alakoso ups owo,3 sipesifikesonu alakoso,abbl. Kaabo lati kan si wa!
Nwa siwaju si ibeere rẹ.